Practical guide · Stormwater storage and discharge

Hydro-Brake Flow Controls

By the end of this lesson

  • Explain how a vortex restricts discharge
  • Connect the flow curve with upstream storage
  • Identify the site information and maintenance provisions needed for selection

Hydro-Brake is a range of flow controls from Hydro International. This guide covers the Hydro-Brake Optimum vortex device. Other products in the range use different control methods.

A vortex is a rotating flow around a central core. In the Optimum device, this flow restricts discharge. The device uses upstream water energy and needs no external power or moving control parts.

1Store water, then release it at a controlled rate

Stormwater is rainwater that runs off surfaces. During a storm, runoff can reach a drainage system faster than its outlet can accept it.

Attenuation means temporary storage that reduces peak discharge. A tank or basin holds the excess water. The outlet flow control determines how quickly that water leaves.

The control does not create storage. If inflow exceeds discharge, stored volume increases. The design must keep the resulting water level below the agreed flood limits.

A pump and a flow control do different jobs

A pump adds energy to move water. A Hydro-Brake uses available head to restrict discharge. Head is energy per unit weight.

If gravity cannot move water to the receiving system, the drainage design also needs a way to provide that lift.

2Understand how the vortex starts

  1. At low water levels, the device behaves like an opening with little vortex action.
  2. As the level rises, the rotating flow begins. During this transition, the vortex can form and collapse.
  3. At higher levels, a stable air core forms. The rotating water restricts the flow through the outlet.
  4. As storage drains, the vortex eventually collapses. The flow then returns toward the behavior of an open outlet.

The device can provide a larger clear opening than a simple orifice for a comparable design duty. An orifice is a fixed opening that restricts flow. A larger opening reduces blockage risk but does not remove it.

3Read the full flow curve

The head-discharge curve relates water head to outlet flow. During vortex formation, discharge can decrease while head rises. After the vortex stabilizes, flow changes along another part of the curve.

Hydro International calls the start of throttling the Flush-Flo point. The Kick-Flo point marks full vortex initiation. The design point gives the specified head and discharge.

Use the complete curve for the selected unit. A single rated flow does not describe its behavior at lower water levels. A generic orifice equation does not reproduce the full vortex curve.

The manufacturer design data sheet shows these stages and the named points.

4Select the device with the storage

A discharge limit alone does not specify the device. Selection also depends on available head and the space available for storage and installation.

  • Record the permitted discharge and the authority that sets it.
  • Record the outlet level and maximum upstream water level. Use the manufacturer reference for the design head.
  • Describe how storage volume changes with water level. Include the inflow over time for the required storm events.
  • Record downstream water levels. Tailwater is water that backs up at the outlet. Ask the manufacturer how submerged discharge affects performance.
  • Record the water type, debris load, chamber dimensions, access, and pipe connections.
  • Obtain the unit curve, dimensions, orientation, and installation instructions from the manufacturer.

Route the changing inflow through the proposed storage and outlet curve. Make sure that the water level, discharge, and time to empty meet the project requirements.

Include the required allowance for future rainfall. Assess blocked outlets, downstream flooding, and the route that excess water takes. A smaller outlet can increase upstream flooding if storage is insufficient.

Use the manufacturer design tool for unit selection. Site approval also depends on the drainage model and local requirements.

5Coordinate it with a pump station

A drainage scheme can need both a flow control and a pump station. Their arrangement depends on the levels, storage, and receiving system.

Do not assume that limiting inflow makes a pump station safe. The restricted water needs space upstream. Make sure that it cannot flood buildings or escape through unintended routes.

If pumps discharge from storage, assess their start and stop levels with the storage model. During a power failure, inflow continues to use the remaining space.

Do not treat the Optimum device as a standard valve in a pressurized force main. Its gravity outlet arrangement and hydraulic curve need a specific design.

6Provide access and maintenance

No moving control parts does not mean no maintenance. Debris, sediment, damage, or an obstructed outlet can change performance.

  • Follow the inspection and cleaning instructions for the supplied unit.
  • Provide access to inspect the inlet, outlet, fixings, and chamber.
  • Record sediment and debris during inspections. Arrange cleaning when conditions require it.
  • If the unit has a bypass, control its use. An open bypass changes the discharge restriction.
  • Keep the unit details, drawings, flow curve, and maintenance records with the drainage system records.

Do not enter a drainage chamber without the required confined space controls. A confined space can contain toxic gas or too little oxygen. Use trained personnel and the site procedure.

Check your understanding

Make sure that you understand flow control

3 auto-graded questions with an explanation for every wrong answer. Requires JavaScript. (hydro-brake-q1)

7Sources and next lessons

For the station calculations, continue with wet well storage, hydraulic profiles, and controls and power failures.

Hydro-Brake Optimum introductory guide · Sources reviewed October 19, 2026