Submergence is the vertical depth from minimum liquid surface to the intake datum defined for the geometry. It suppresses the air path of a free-surface vortex, but adequate depth alone cannot correct a poor approach channel, asymmetric walls or strong pre-rotation. Floor clearance is a different dimension with a different failure.
Layouts are often reviewed with ratios such as S/D and C/D, where submergence S, clearance C and inlet diameter D use the same units. Required ratios depend on inlet Froude number, arrangement, approach velocity and governing intake criteria; obtain them from the applicable standard or manufacturer rather than universalising one value.
Measuring from the floor overstates usable submergence and conceals inadequate bell clearance. Raising the pump-off level may suppress a vortex, but if one parallel pump remains rough the root cause may be asymmetric approach flow rather than insufficient average depth.
§8.3 diagnoses vortex symptoms; §8.1 coordinates control levels.
Physics sets the relationships; the owner, manufacturer and governing local standard set the project criteria.