Static head is the elevation the liquid must gain before friction is counted. For two open reservoirs it is the vertical difference between water surfaces, not the difference between pump flanges or pipe inverts. Because a wet well draws down and a tank or receiving system can move, a station normally has a static-head range rather than one immutable value.
For open boundaries, Hstatic = z2 − z1, in metres of liquid (ft of liquid). For pressurised boundaries, include pressure head: Hboundary = (z2 + p2/ρg) − (z1 + p1/ρg). Use pressures on the same gauge or absolute basis so atmospheric pressure cancels correctly.
Measuring between nozzles makes pump location appear to change the duty, violating the boundary energy balance. A second failure is to use normal levels only: the selected pump may miss capacity at low source/high discharge level or overload at the opposite end.
See §2.3 for the moving range and §2.5 for its place in total dynamic head.
Physics sets the relationships; the owner, manufacturer and governing local standard set the project criteria.