Concept reference
Parallel pumps share suction and discharge nodes, so their flows add at the same head. Series pumps pass the same flow, so their heads add. Neither rule says the installed station will deliver double: the combined curve must still intersect a rising system curve.
For parallel operation, Qtotal(H) = ΣQi(H). For series operation, Htotal(Q) = ΣHi(Q). These relations combine pump curves before intersection with Hsystem(Q). Unequal units require individual curves, check-valve logic and review of each pump’s operating point.
Adding rated flows ignores the extra friction created by the combined flow. Unequal parallel pumps can drive a smaller unit toward shutoff, reverse flow or an unacceptable region; identical nameplates also do not guarantee identical field curves after wear or trimming.
§7.3 quantifies the missing “second-pump” flow; §4.5 treats unequal branches.
Physics sets the relationships; the owner, manufacturer and governing local standard set the project criteria.