Concept reference
A “minor” loss is energy dissipated where the flow turns, separates, accelerates or mixes. The name describes long pipelines where straight-pipe friction dominates; inside a compact station, fittings and valves can own much of the loss. A K value is a measured or modelled count of velocity heads, not a universal label attached to a symbol.
hm = K Vref²/(2g) and hminor,total = ΣK · Vref²/(2g) only when the coefficients share the same reference velocity. Equivalent length uses Le/D = K/f, so it inherits a friction factor and is not constant across every flow and roughness.
Summing K values referenced to different diameters silently corrupts the schedule. Generic coefficients can also hide valve type, opening, reducer geometry or manufacturer-specific behaviour; a half-open valve is not the tabulated fully open device.
Physics sets the relationships; the owner, manufacturer and governing local standard set the project criteria.