Best efficiency point (BEP) is the peak of a particular pump’s efficiency curve at a particular speed and impeller. Near it, approach and impeller flow patterns are generally well aligned. Distance from BEP is a useful warning about recirculation, radial load, vibration and energy, but it is not a universal pass/fail percentage.
At any point, ηp = ρgQH/Pshaft. BEP is where this measured ratio reaches its maximum for the tested curve. Manufacturers or applicable pump standards define preferred and allowable operating regions for a particular machine; those documented limits take precedence over copied generic bands.
Choosing the pump whose catalogue BEP matches one design flow can still leave most annual operation far away because wet-well levels, staging and demand vary. Conversely, treating BEP as the only permitted point can force poor controls or unnecessary equipment.
Physics sets the relationships; the owner, manufacturer and governing local standard set the project criteria.